In previous blogs we have defined Cavitation and reviewed Discharge Cavitation.  In this blog I would like to discuss a specific type of discharge recirculation known simply as “Total Discharge Recirculation” or “TDR” for short. 

All forms of pump recirculation, as the term denotes, evolve some portion of the liquid not following the desired path.  When referencing total discharge recirculation, the difference is that none of the liquid is following the desired path. To be more exact, there is absolutely no liquid leaving the pump enclosure.

TDR is typically the result of a discharge valve accidentally being completely closed during operation or a static head that exceeds the pumps maximum head output (shut off condition). Under these conditions the energy transferred from the motor or engine is being converted  to heat energy within the liquid and is not allowed to escape from the pump enclosure. If not rectified TDR can quickly result in highly elevated temperatures within the pump. With the casing pressure at shut off point we effectively now have a pressure vessel and temperatures can continue to rise well past boiling point (100 degrees C).

The build up of heat is conducted through the casing into all parts of the pump. Although the heat can directly damage the seal surfaces, degrade lubricating oil and cause bearing bind or softening of connected piping (plastic), the real damage potential will be the result of thermal shock.

Should the blockage be abruptly removed and cold liquid introduced into a hot pump the sudden temperature change is highly likely to crack a mechanical seal face and may even crack the pump casing.

Learn about the industrial pumps that Hevvy Pumps has to offer your project:

Read the Slurry pump maintenance guide to learn how to maintain your slurry pump for optimal performance. View slurry pumps in USA options.

Talk to Hevvy Pumps for more information.

In the next blog we will discuss “Thermal Shock” and how to avoid damage when cooling a pump down after TDR.

Until Next Time,

RJ

In our last blog we discussed cavitation singling out suction cavitation to illustrate the concept. In this blog, as promised, we will discuss discharge recirculation, also sometimes referred to as discharge cavitation. 

The term discharge recirculation is often used interchangeably with the term discharge cavitation.  Although these two are clearly related they have a few distinct differences. 

Let us first examine discharge recirculation. The term simply describes an operating condition within a centrifugal pump where significant portions of the design flow is not exiting out of the discharge. This occurs when the operating point is well to the left of the BEP, approaching or even reaching shut off conditions.  The reference to recirculation actually applies to two distinct locations or types of recirculation within the pump.

One of the two locations is at the pumps splitter or cut water.  With lower than design flow exiting out of the discharge, large volumes of liquid are forced to recirculate within the casing.  A high flow rate passing through the small gap between the impeller and the volute’s cut water results in a high fluid velocity.  The extreme velocity at this location causes a vacuum to develop at the housing wall (similar to what occurs in a venturi), which turns the liquid into a vapour. 

The drawing below illustrates this issue:

The vapour bubbles forming and then collapsing as they move away from the low pressure zone is a process we described last blog as cavitation. Due to its location, this form of cavitation is labelled as “volute discharge cavitation”.  

The second location for discharge recirculation to occur is in the impeller vane. Similar to cutwater recirculation, it becomes more of an issue as the operating point approaches shut off conditions.  As illustrated, discharge recirculation is the reversal of flow at the discharge tips of the impeller blades. 

The high shear rate between the inward and outward relative velocities produces vortices. The fluctuation in pressure that occurs within these vortices results in the formation and collapse of vapour bubbles.  Again, this is the definition of cavitation and in this second location it is noted as “impeller discharge cavitation”.

On a separate note; a problem referred to as “vane passing syndrome” is almost identical to the discharge recirculation issue as described at the beginning of this blog. There is however a fine distinction. Vane passing syndrome is normally associated with pumps being designed with a closed impeller to split water clearances that can suffer from cavitation issues at close to BEP flow rates. This is of course different than plain recirculation that is normally associated at conditions from 10% of BEP flow to shut off.